What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LEFT ELEVATOR UPPER SKIN AT XRS 218.8 CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED SKIN ON LEFT ELEVATOR AT XRS 218.8 IAW DC9 SRM 51-10-03, 55-03 FIG 14, AND 51-30.