What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND A CRACK UNDER THE VENTRAL STAIR ACTUATOR ON THE FRAME AT BS 1145R. CUT OUT AND REMOVED CRACKED SECTION OF FRAME AND FABRICATED FRAME SPLICE AT BS 1145R IAW EO 99-1405, DC9 SRM 51-1 0-02, AND DC9 MM 52-63.