What was found
(AUS) ENGINE DRIVEN FUEL PUMP CONTAMINATED. INVESTIGATION FOUND CONTAMINATION WAS RUST FROM THE INTERNAL BORES OF THE STEEL END FITTINGS OF THE FLEXIBLE HOSES AND FIREWALL FITTINGS IN THE FUEL SUPPLY SYSTEM PLUMBING. SUBMITTER SUSPECTED RUST PROBLEM IS ASSOCIATED WITH THE DECONTAMINATION OF THE FUEL SYSTEM WITH WATER FOLLOWING THE MOBIL FUEL CONTAMINATION PROBLEM. (X)