Service difficulty report · Circuit Breaker · Boeing 737800*

Difficulty date
December 12, 2005
Submitted
June 6, 2006
Operation
General aviation
Make and model
Boeing 737800*
Engine
Ge CFM56*
Part
Circuit Breaker
Condition
Tripped
Location
Apu Fire Exting
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU FIRE EXTINGUISHING SYSTEM CIRCUIT BREAKER PULLED AND RED COLLARED. CIRCUIT BREAKER RESET AND SYSTEM TESTED SERVICEABLE. SUSPECT CIRCUIT BREAKER PULLED WHEN MEL APPLIED AND NOT RESET WHEN MEL CLEARED.