SDR AU961114

Service difficulty report · Actuator · Airbus A320212

Difficulty date
June 21, 1996
Submitted
March 26, 2000
Operation
General aviation
Make and model
Airbus A320212
Part
Actuator
Part number
VFT210700
Condition
Corroded
Location
Press. Regul/Out
Stage of operation
CL
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(AUS) AVIONICS VENT SYSTEM SKIN AIR INLET VALVE ACTUATOR INOPERATIVE - SUSPECT CAUSED BY CORROSION BUILDUP ON THE CLOSED POSITION LIMIT MICROSWITCH (S2)

More about the Airbus A320-212