What was found
(AUS) FUSELAGE FRAME 18 CONTAINED STRESS CORROSION AND CRACKING IN FLANGES. A HOLE MEASURING 63.5 MM BY 25.4 MM (2.5 INCHES BY 1 INCH) WAS FOUND JUST BELOW FLOOR LEVEL AT THE RT SERVICE DOOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(AUS) FUSELAGE FRAME 18 CONTAINED STRESS CORROSION AND CRACKING IN FLANGES. A HOLE MEASURING 63.5 MM BY 25.4 MM (2.5 INCHES BY 1 INCH) WAS FOUND JUST BELOW FLOOR LEVEL AT THE RT SERVICE DOOR.