What was found
(AUS) FORWARD PRESSURE BULKHEAD LOCATED AT STA 178 CRACKED IN THE FOLLOWING LOCATIONS: 1. CRACK LOCATED ON THE INBOARD SIDE RADIUS OF THE LT VERTICAL CHORD (LBL 5.7) AND WL184 ON THE AFT SIDE OF THE BULKHEAD - CRACK LENGTH 9.525 MM (0.375 INCH). 2. CRACK LOCATED IN THE RT SIDE CHORD RADIUS AT WL 207 ABOVE AND BELOW FLOOR LEVEL - CRACK LENGTH 31.75 MM (1.25 INCH) FOUND DURING EDDY CURRENT INSPECTION IAW ER B73-53-10-39D.