What was found
(AUS) STRINGER NR 41L LOCATED BELOW FORWARD CARGO AREA BETWEEN FRAME 30 AND FRAME 31 CONTAINED LEVEL 2 CORROSION. AREA OF CORROSION 127MM (5IN) BY 25.4MM (1IN) AND 0.8636MM (0.034IN) DEEP. FOUND DURING INSPECTION IAW MRBR 53.21.80.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(AUS) STRINGER NR 41L LOCATED BELOW FORWARD CARGO AREA BETWEEN FRAME 30 AND FRAME 31 CONTAINED LEVEL 2 CORROSION. AREA OF CORROSION 127MM (5IN) BY 25.4MM (1IN) AND 0.8636MM (0.034IN) DEEP. FOUND DURING INSPECTION IAW MRBR 53.21.80.