What was found
(AUS) CABIN FLOOR STRUCTURE CONTAINED LEVEL 2 CORROSION IN THEFOLLOWING AREAS:- 1. DOOR CUTOUT REAR RADIUS AT L1 DOOR2. CENTRE ATTACHMENT ANGLE (LOCATED BETWEEN FORWARD AND REAR RADIUS OF L1 DOOR GUSSETS 3. LT REAR PASSENGER DOOR SILL. RT OUTBOARD SEAT TRACK AT SIX LOCATIONS BETWEEN FR18 AND FR215. RT REAR DOOR SILL AREA AT- A. REAR GUSSET (RADIUS) SILL. CENTRE STRIP BETWEEN FORWARD AFT GUSSET.