Service difficulty report · Splice · Bac 146200A

Difficulty date
July 15, 2003
Submitted
January 5, 2004
Operation
General aviation
Make and model
Bac 146200A
Engine
Lyc ALF502R5
Part
Splice
Part number
121972
Condition
Damaged
Location
Ac Power
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(AUS) IDG FEEDER CABLE INLINE SPLICE WAS PRE SB-24-85-01253A. PRE MOD SPLICES PN 12197/2 WERE FITTED INSTEAD OF PN 12198/2 SPLICES.