What was found
APPROX 1.5 INCH CRACK EXTENDING FROM CENTER WEB OF FWD PRESS BULKHEAD STA 178, JUST ABOVE WL 207 RBL 1-2.5. CUT OUT DAMAGE IAW SRM 53-10-08, NO CRACK NOTED IAW B737 NTM PT.6 51-00-00 FIG 23; FABBED REPAIR DOUBLER, FILLERS, AND SHIMS IAW 53-10-08 FIG 209; TREATED IAW 51-20-01; INSTALLED IAW 51-40-02; SEALED IAW 51-20-05.