As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT PYLON I/B AT FRAME TOP SURFACE AT PANEL 5735L GOUGED BEYOND LIMITS AT I/B FASTNER. BLENDED GOUGE IAW 57-20-01 AND EO 03-1754-00355; ALL FABED SHIM AND FLAP PEENED IAW SOPM 20-10-03 AWA ER 03-5754-00333-001; HFC NO CRACKS NOTED ; INSTALLED SHIM IAW 51-40-02