What was found
SKIN SHEAR TIE AT FRAME 23L AND STR 22L CRACKED .200 IN LOWER TWO RADIUS. CLEAT FABED, HEAT TREATED AND INSTALLED IAW SRM 51-26-11
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SKIN SHEAR TIE AT FRAME 23L AND STR 22L CRACKED .200 IN LOWER TWO RADIUS. CLEAT FABED, HEAT TREATED AND INSTALLED IAW SRM 51-26-11