What was found
CORROSION ON FLOORBEAM AT STA 294 LBL 3 FOUND DURING CPCP INSPECTION EVALUATED AS LEVEL 1. CORROSION REMOVAL IAW SRM BEYOND LIMITS; REPAIRED FLOORBEAM IAW SRM 53-10-51 PG 220-222 FIG 205 SHT.3-4; PREPPED AND PAINTED IAW MM51-21-00
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT STA 294 LBL 3 FOUND DURING CPCP INSPECTION EVALUATED AS LEVEL 1. CORROSION REMOVAL IAW SRM BEYOND LIMITS; REPAIRED FLOORBEAM IAW SRM 53-10-51 PG 220-222 FIG 205 SHT.3-4; PREPPED AND PAINTED IAW MM51-21-00