What was found
CABIN FLOORBEAM STA 328 LBL 28 FWD SIDE OF FLOORBEAM HAS CRACKED STIFFENER. REMOVED STIFFENER IAW SRM 51-40-02; FABED STIFFENER ANGLE; TREATED, ALODINED & PRIMED AND TOPCOAT IAW 51-20-01; INSTALLED STIFFENER IAW 51-40-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM STA 328 LBL 28 FWD SIDE OF FLOORBEAM HAS CRACKED STIFFENER. REMOVED STIFFENER IAW SRM 51-40-02; FABED STIFFENER ANGLE; TREATED, ALODINED & PRIMED AND TOPCOAT IAW 51-20-01; INSTALLED STIFFENER IAW 51-40-02