What was found
STR CRACKED AT END FASTENER HOLE FUSE STA 500D + 15 INCHES, STR 16R. CUT OUT DAMAGED AREA OF STR; FABED REPAIR CHANNEL AND RADIUS FILLER; INSTALLED IAW AWA ER 03-5310-01003-JS2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR CRACKED AT END FASTENER HOLE FUSE STA 500D + 15 INCHES, STR 16R. CUT OUT DAMAGED AREA OF STR; FABED REPAIR CHANNEL AND RADIUS FILLER; INSTALLED IAW AWA ER 03-5310-01003-JS2.