What was found
FWD CARGO PIT UPPER FLOORBEAM STA 560 RBL 0 INTERCOSTAL CRACKED. REMOVED, FABED AND INSTALLED ANGLE IAW SRM 53-30-51, 51-30-02, AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT UPPER FLOORBEAM STA 560 RBL 0 INTERCOSTAL CRACKED. REMOVED, FABED AND INSTALLED ANGLE IAW SRM 53-30-51, 51-30-02, AND 51-40-02.