What was found
FWD PRESSURE BLKHD INTERCOSTAL CRACKED AT STA 178 WL 195 LT SIDE (1 INCH CRACK) FWD CORNER. REPLACED INTERCOSTAL IAW DWG 65-16300 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PRESSURE BLKHD INTERCOSTAL CRACKED AT STA 178 WL 195 LT SIDE (1 INCH CRACK) FWD CORNER. REPLACED INTERCOSTAL IAW DWG 65-16300 AND SRM 51-30-2.