What was found
FUSELAGE LT SIDE CHORD AT WL 207 STA 178 CRACKED. INSTALLED NEW CHORD IAW SRM 51-40-02 PG 1, 2, 9, 10 W/ REF TO DWG 65-16300 SHEET 5 FRAME 1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE LT SIDE CHORD AT WL 207 STA 178 CRACKED. INSTALLED NEW CHORD IAW SRM 51-40-02 PG 1, 2, 9, 10 W/ REF TO DWG 65-16300 SHEET 5 FRAME 1-8.