What was found
ULTRASONIC INSP REVEALS CRACK VERT POSITION AT I/B EDGE LBL 5.7 AT WL 234 BS 178 LOCATION .75 INCH LENGTH. REPAIRED IAW SRM 53-10-11 FIG 1 DETAIL III AND SRM 51-30-2 PG 5 AND REF DWG 65-16300.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ULTRASONIC INSP REVEALS CRACK VERT POSITION AT I/B EDGE LBL 5.7 AT WL 234 BS 178 LOCATION .75 INCH LENGTH. REPAIRED IAW SRM 53-10-11 FIG 1 DETAIL III AND SRM 51-30-2 PG 5 AND REF DWG 65-16300.