What was found
HFEC INDICATES .2 INCH CRACK EMANATING FROM BENEATH STRAP BS 178 BLKHD FORWARD SIDE WL 198.6-198.8 RBL 4.7. CUT OUT DAMAGED WEB; LOCATED, DRILLED, TRIMMED AND INSTALLED REPAIR DOUBLER IAW SRM 53-10-08 PG 287-298.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HFEC INDICATES .2 INCH CRACK EMANATING FROM BENEATH STRAP BS 178 BLKHD FORWARD SIDE WL 198.6-198.8 RBL 4.7. CUT OUT DAMAGED WEB; LOCATED, DRILLED, TRIMMED AND INSTALLED REPAIR DOUBLER IAW SRM 53-10-08 PG 287-298.