What was found
PASSENGER CABIN FLOORBEAM BS 377, BL 0 TO LBL 24, UPPER T-CAP TOP FLANGE AND LOWER SURFACE CORRODED. CUT OUT DAMAGED SECTION OF UPPER T-CAP FLOORBEAM. FABRICATED NEW SECTION OF BEAM AND REPAIR SPLICE ANGLES AND INSTALLED ALL THE NEW REPAIR PARTS AND PREVIOUSLY REMOVED FLOOR STRUCTURE IN SURROUNDING AREA IAW B757 SRM 53-00-51, FIG 203 & B757 SRM 51-40-2. NEW SECTION FROM RBL 35 RO LBL 72, STA 377.