What was found
MCN - C12 CK - "C" - EXTERNAL SKIN HAS 3.9" X 1.9" DENT AT BS 727D TO 727E, STR 22 L/H TO 23 L/H. MAINTENANCE CONFIRMED THE DENT WAS OUT OF LIMIT USING 737-300 SRM 53-00-01, PG 104. DAMAGED AREA OF SKIN WAS CUT OUT AND A HFEC INSPECTION WAS PERFORMED TO CHECK FOR CRACKS, (NONE WERE FOUND). REPAIR PLATE WAS FORMED AND INSTALLED IAW B737-300 SRM 53-00-01, PG 204-206.