What was found
MCN - C12 CK - "C" - FUSELAGE SKIN HAS .4" X .080" GOUGE .019 DEEP AT BS 1004.75, STR 2L. GOUGE MEASURED OUT OF LIMITS PER B737-300 SRM 53-00-01, FIG 101, DETAIL II, PG 104. MAINTENANCE REMOVED 3 STRINGER CLIPS, 2 BRACKETS, AND A STRINGER END FITTING AT STR 2L BETWEEN BS 986 AND 1016. GOUGED AREA OF SKIN WAS CUT OUT AND HFEC INSPECTION WAS ACCOMPLISHED TO CHECK FOR CRACKS (NO CRACKS WERE FOUND). FABRICATED AND INSTALLED -1 DOUBLER AND -2 STRINGER AT BS 1004.75 STR 2L, IAW B737-300 SRM 53-00-01, PG 201, AND SRM 51-40-02, PG 3-4. REINSTALLED 3 STRINGER CLIPS, STRINGER END FITTING, AND 2 BRACKETS AT STR 2L BETWEEN BS 986 AND 1016, IAW 737-300 SRM 51-40-02 PG 10-11 & 74.