What was found
MCN - MAJOR REPAIR - DURING C-15 CHECK MAINTENANCE DISCOVERED WEB ON LONGITUDINAL FLOOR BEAM CRACKED IN 4 PLACES, BS 706, LBL .07. MAINTENANCE REMOVED 4 EACH WEB STIFFNERS (BS 700, 706, 711, 715) AND DAMAGED SECTION OF FLOOR BEAM WEB AT LBL .07 BS 700 TO 715. FABRICATED AND INSTALLED FLOOR BEAM WEB, DOUBLER, AND 4 EACH STIFFNERS AT (BS 700, 706, 711, 715) IAW AWA ER 03-5702-01353-TB2.