What was found
YVR - MAJOR REPAIR -C- DURING C-13 CHECK A 1 INCH CRACK WAS FOUND WHERE FLOOR SUPPORT L-ANGLE ATTACHES TO BELT FRAME AND FLOORBEAM AT BS 639, WL 208. MAINTENANCE REMOVED DAMAGED SECTION OF INNER CHORD; FABRICATED NEW SECTION OF INNER CHORD AND SPLICE PARTS; INSTALLED REPAIR IAW IAW B737-300 SRM 51-70-12, FIG 1 PG 1, DWG 65-47973, SRM 51-40-02, PG 3 AND TELEX AWM-YVR-02-00017H.