What was found
YVR - MAJOR REPAIR - C - DURING C-13 CHECK A 4 INCH CRACK WAS FOUND ON CREASE BEAM WEB RT BS 616 - 639. MAINTENANCE REMOVED DAMAGED CREASE BEAM WEB AND FITTED AND INSTALLED A NEW BEAM WEB IAW DWG 65-47973 AND SRM 51-40-2 PG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
YVR - MAJOR REPAIR - C - DURING C-13 CHECK A 4 INCH CRACK WAS FOUND ON CREASE BEAM WEB RT BS 616 - 639. MAINTENANCE REMOVED DAMAGED CREASE BEAM WEB AND FITTED AND INSTALLED A NEW BEAM WEB IAW DWG 65-47973 AND SRM 51-40-2 PG 3.