What was found
YVR - MAJOR REPAIR - "C" - DURING C-13 CHECK TWO SMALL DENTS WERE FOUND JUST ABOVE AND AFT OF THE FWD LAVATORY SERVICING DOOR BS 294. MAINTENANCE PERFORMED HFEC INSPECTION TO VERIFY DENTS WERE NOT CRACKED, NO CRACKS NOTED, FABRICATED AND INSTALLED REPAIR DOUBLER, FILLER, AND TRIPLER AS PER AWA ER 03-5311-01233-SS2E.