What was found
YVR - MAJOR REPAIR - DURING C-20 CHECK THE R/H MAIN LANDING GEAR UPLOCK BUSHING FITTINGS WERE FOUND WORN BEYOND LIMITS, BS 685. MAINTENANCE REMOVED BUSHINGS AT BS 685 & 695, FOUND CORROSION IN BUSHING BORE BS 685, MACHINED TO REMOVED CORROSION, FABRICATED 2 EA. REPAIR SLEEVES, INSTALLED SLEEVES AND FLAP PEENED PER SOPM 2010-03, INSTALLED NEW BUSHINGS. REPAIR PERFORMED IAW AWA ER 15-5364-02115-TB3.