Service difficulty report · Pump · Boeing 7373S3

Difficulty date
June 15, 2002
Submitted
September 12, 2002
Operation
Air carrier
Aircraft
N316AW
Make and model
Boeing 7373S3
Aircraft serial
23713
Aircraft time
51,070 hours, 31,847 cycles
Part
Pump
Part number
5509808
Part serial
115995AK
Condition
Leaking
Location
Nr 2 Engine
Part time
64,324 hours, 63,156 cycles
Stage of operation
CL
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PHX - AIR TURN BACK - FLT 0320 - ON DEPARTURE FROM PHX EN ROUTE FOR ACA THE HYDRAULIC PUMP B-ENGINE NR 2 LIGHT ILLUMINATED. B-SYSTEM HYDRAULIC QUANTITY DROPPED TO APPROXIMATELY 3/8 FULL, PRESSURE WAS GOOD. MAINTENANCE FOUND NR 2 ENGINE DRIVEN HYDRAULIC PUMP LEAKING. REMOVED AND REPLACED NR 2 ENGINE HYDRAULIC PUMP, PERFORMED ENGINE RUNS, NO MALFUNCTIONS OR LEAKS NOTED PER TASK CARD R5M29002. HYDRAULIC PUMP WAS CONFIRMED FAILURE BY VENDOR.

More about the Boeing 737-3S3