What was found
MCN - MAJOR REPAIR - DURING C-14 CHECK A SHORT EDGE MARGIN WAS FOUND ON THE AFT ENTRY DOOR STOP FITTING BS 954, STR 11 L/H. MAINTENANCE REMOVED THE AFT ENTRY DOOR STOP FITTING AND TRIMMED DAMAGE AT THE END OF CLOSE OUT PLATES. FABRICATED 2 EACH FILLERS, 2 EACH -1 STRAPS, 2 EACH -2 FRAME SPLICE STRAPS, AND INSTALLED REPAIR PARTS IAW AWA ER 03-5300-02165-JS4.