What was found
PHX - AIR TURN BACK - FLT 7811 - ON TAKEOFF FROM PHX EN ROUTE TO SFO PRIOR TO 3000 FT, PRESSURE AUTO FAIL LIGHT ILLUMINATED AND WHILE PASSING 7000 FT THE #1 GENERATOR BUS FAILED, VOLTS AND FREQUENCY CHECKED OK. GENERATOR WAS BROUGHT BACK ONLINE AT THIS TIME AND THE #1 TRANSFORMER RECTIFIER (TR) AND NORMAL EQUIPMENT COOLING CIRCUIT BREAKERS WERE FOUND POPPED. AIRCRAFT RETURNED TO PHX. MAINTENANCE REPLACED THE #1 ENGINE GENERATOR CIRCUIT BREAKER, AND DURING ENGINE RUN WITH #1 TR AND #1 GENERATOR EQUIPMENT COOLING NORMAL, THE "B" SYSTEM ELECTRIC PUMP C/B POPPED AND #1 GENERATOR CYCLED ON AND OFF. MAINTENANCE REPLACED THE #1 ENGINE 40KVA ELECTRIC GENERATOR IAW T/C R5M24002, THE GENERATOR BUS TIE BREAKER, AND THE GE