What was found
MCN - MAJOR REPAIR - DURING C-18 CHECK HFEC INSPECTION IDENTIFIED A 1 5/8" CRACK RUNNING FROM A FASTENER HOLE ON THE FORWARD FRAME AT THE PAN COMMON TO THE #3 STOP OF THE L2 DOOR, BS 956. MAINTENANCE TRIMMED OUT CRACK IN FRAME AT BS 956. PERFORMED A HFEC INSPECTION TO VERIFY NO CRACKS EXIST. FABRICATED 3 EACH REPAIR FILLERS, A REPAIR ANGLE, A SEAL FITTING, AND A STRAP, AND INSTALLED REPAIR PARTS IAW AWA ER 03-5330-02197-SS3.