What was found
YVR - MAJOR REPAIR - DURING C-20 CHECK A .125 INCH CRACK WAS FOUND ON THE FORWARD ENTRY DOOR CUTOUT FRAME AT BS 312, STR 6 LT. MAINTENANCE BLENDED OUT CRACK ON FORWARD ENTRY DOOR CUTOUT FRAME AT BS 312, STR 6 LT. HFEC INSPECTION VERIFIED CRACK NO LONGER EXISTS.