What was found
LCQ - MAJOR REPAIR - DURING C-08 CHECK A 1.25 INCH CRACK WAS FOUND ON FLOORBEAM SUPPORT ANGLE BETWEEN BS 660 - 680. MAINTENANCE REMOVED CRACKED FLOORBEAM SUPPORT ANGLE, FABRICATED A NEW FLOOR SUPPORT ANGLE, AND INSTALLED REPAIR IAW B757-200 SRM 51-10-02, PG 15 AND SRM 51-40-02, PG 8, 11-12.