What was found
DURING INSPECTION THE EMERGENCY LIGHTS IN FIRST CLASS, L-1, AND R-1 DOORS WERE FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (10WL) AND BATTERY, OPERATIONAL CHECK WAS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION THE EMERGENCY LIGHTS IN FIRST CLASS, L-1, AND R-1 DOORS WERE FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (10WL) AND BATTERY, OPERATIONAL CHECK WAS GOOD.