Service difficulty report · Outflow Valve · Airbus A319132

Difficulty date
March 11, 2003
Submitted
March 12, 2003
Operation
Air carrier
Aircraft
N807AW
Make and model
Airbus A319132
Aircraft serial
1064
Aircraft time
13,437 hours, 5,415 cycles
Part
Outflow Valve
Part number
VFT300B00
Part serial
2103
Condition
Malfunctioned
Location
Zone 126
Part time
13,431 hours, 5,412 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF FROM PIT EN ROUTE FOR PHX RECEIVED ECAM MESSAGE FOR VENT SKIN AIR VALVE FAULT. COMPLIED WITH ECAM INSTRUCTIONS AND DIVERTED TO CMH. MAINTENANCE FOUND AVIONICS EQUIPMENT VENTILATION COMPUTER (AEVC) FAULTING 22HQ SKIN/AIR VALVE. VALVE WAS PREVIOUSLY ON MEL AND WAS LOCKED OUT. REMOVED AND REPLACED SKIN/AIR VALVE IAW T/C R2A21301. DURING OPERATIONAL TEST PRESSURE SWITCH 17HQ FAULTED, REMOVED AND REPLACED PRESSURE SWITCH IAW AMM 21-26-11-04. OPERATIONAL TEST OF AEVC SYSTEM WAS GOOD PER T/C F1B21301. PART NAME; SWITCH PRESSURE, MFG; IN LHC GROUPE, P/N 1209-100, LOC; ZONE 121.