What was found
DURING C-16 CHECK A 1 INCH CRACK WAS FOUND ON FORWARD END OF INTERCOSTAL BETWEEN FLOORBEAMS AT BS 328 AND BS 344, LBL 46. MAINTENANCE REMOVED DAMAGED INTERCOSTAL BETWEEN FLOORBEAMS AT BS 328 AND BS 344, LBL 46; FABRICATED A NEW REPLACEMENT INTERCOSTAL; INSTALLED REPAIR PART IAW B737-300 SRM 51-10-02, PG. 12.