Service difficulty report · Shutoff Valve · Boeing 7373S3

Difficulty date
April 10, 2003
Submitted
April 11, 2003
Operation
Air carrier
Aircraft
N312AW
Make and model
Boeing 7373S3
Aircraft serial
24060
Aircraft time
38,573 hours, 28,435 cycles
Part
Shutoff Valve
Condition
Inoperative
Location
Nr 1 Bleed Sys
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MCI - ABORTED TAKEOFF - FLT 702 - PREPARING FOR TAKEOFF AT MCI EN ROUTE FOR PHX LT BLEED PRESSURE INDICATED ZERO, TAXIED OFF RUNWAY AND RETURNED TO GATE. MAINTENANCE ISSUED MEL 36-5, COND 2, NR 1 ENG BLEED AIR SHUTOFF VALVE INOP. WHEN AIRCRAFT RETURNED TO PHX MAINTENANCE LUBRICATED THE VALVE AND PERFORMED AN ENGINE RUN OPERATIONAL CHECK OUT, BLEED OPERATION AND PRESSURE WAS NORMAL.