What was found
LCQ - MAJOR REPAIR - DURING C-09 CHECK INTERGRANULAR CORROSION WAS FOUND ON LOWER SURFACE OF AFT CARGO COMPARTMENT FLOORBEAM AT BS 1469, RBL 16. MAINTENANCE FOUND CORROSION TO BE ON EXISTING REPAIR ANGLE; REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT LIMITS; REMOVED CORRODED REPAIR ANGLE AT BS 1469, RBL 16; FABRICATED A NEW REPLACEMENT REPAIR ANGLE; INSTALLED REPAIR PART IAW 51-70-11, PG. 1-7, FIG. 1.