What was found
DURING C-13 CHECK 3 EACH 1 INCH CRACKS WERE FOUND ON BS 178 BULKHEAD WEB AT RBL 5, WL 197.75 - 198.75, WL 201 - 201.75, AND RBL 6.25, WL 200.75 - 201.5. MAINTENANCE STOP DRILLED CRACKS ON BS 178 BULKHEAD WEB AT RBL 5, WL 197.75 - 198.75, WL 201 - 201.75, AND RBL 6.25, WL 200.75 - 201; PERFORMED HFEC INSPECTION OF STOP DRILL HOLES TO VERIFY CRACKS ARE CONTAINED; FABRICATED A REPAIR DOUBLER; INSTALLED REPAIR PARTS IAW B737-300 SRM 53-10-08, FIG. 210, PG. 275-278.