What was found
DURING C-04 CHECK A 4.75 INCH CRACK WAS FOUND ON FLOOR WEB BETWEEN FR 68-69, Y1270. MAINTENANCE REMOVED DAMAGED FLOOR WEB BETWEEN FR 68-69, Y1270; FABRICATED A NEW REPLACEMENT FLOOR WEB; INSTALLED REPAIR PART IAW A320 SRM 51-42-11, PG 21-22, FIG 8.