What was found
DURING C-14 CHECK A 1 INCH CRACK WAS FOUND ON FRAME INNER CHORD AT BS 616, RBL 45, WL 200. MAINTENANCE CUT OUT CRACK ON FRAME INNER CHORD AT BS 616, RBL 45, WL 200; PERFORMED A HFEC INSPECTION TO VERIFY NO CRACKS EXIST; FABRICATED A STIFFENING ANGLE AND FILLER; INSTALLED REPAIR PARTS IAW AWA ER 03-5311-01143-DD1.