What was found
DURING B-02 CHECK A .75 INCH CRACK WAS FOUND ON PANEL ATTACH ANGLE AT OUTBOARD SIDE OF NR 1 PYLON, RIB 8. MAINTENANCE CUT OUT DAMAGE ON ATTACH ANGLE AT OUTBOARD SIDE OF NR 1 PYLON, RIB 8; FABRICATED A REPAIR ANGLE AND FILLER; INSTALLED REPAIR PARTS IAW A319 SRM 54-52-12, PG 215-220, FIG 203.