What was found
MCN - MAJOR REPAIR - DURING C-14 CHECK EXFOLIATION CORROSION WAS FOUND ON UPPER SURFACE OF FLOOR SUPPORT AT BS 976, RBL 17, WL 208. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED FLOOR SUPPORT FROM BS 976 TO BS 977; FABRICATED A NEW REPLACEMENT SECTION OF FLOOR SUPPORT; INSTALLED REPAIR PART IAW B737-300 SRM 53-60-51, PG 105-100, FIG 101, AND SRM 51-40-02, PG 10-11, & 44-45, FIG 12.