What was found
DURING C14 CHECK A PITTING CORROSION WAS FOUND UPPER SURFACE OF L-2 DOORWAY INNER STRUCTURE AT BS 987, LBL 53, WL 208. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED INNER STRUCTURE AT LBL 53 FROM BS 917 TO BS 1016; FABRICATED A NEW REPLACEMENT INNER CHORD; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02, FIG 8, PG 3-4, 11 & 38.