What was found
MCN - MAJOR REPAIR - DURING C-14 CHECK A .25 INCH CRACK WAS FOUND AT UPPER EDGE OF ATTACH ANGLE, JUST BELOW FLOOR AT BS 639, LBL 46. MAINTENANCE REMOVED ATTACH ANGLE FROM FLOORBEAM AT BS 639, LBL 46; FABRICATED A NEW REPLACEMENT ATTACH ANGLE PER DWG 65-46540; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02, PG 1, SECT 7, & PG 45, FIG 12, SHT 2.