What was found
DURING C-16 CHECK A 1/8 INCH CRACK WAS FOUND ON BEAM WEB AT INSULATION MOUNT HOLE BS 184, RBL 17.1, WL 178. MAINTENANCE CUTOUT DAMAGED AREA OF VERTICAL BEAM WEB AT BS 184, RBL 17.1, WL 178, AND PERFORMED A HFEC INSPECTION OF CUTOUT TO VERIFY NO CRACK EXISTS; FABRICATED A - 3 DOUBLER & -5 WEB; INSTALLED REPAIR PARTS IAW B737-200 SRM 51-10-11, PG. 1, FIG. 011.