Service difficulty report · Control Unit · Airbus A319132

Difficulty date
August 30, 2003
Submitted
September 2, 2003
Operation
Air carrier
Aircraft
N829AW
Make and model
Airbus A319132
Aircraft serial
1563
Aircraft time
7,314 hours, 2,837 cycles
Part
Control Unit
Part number
350E550020
Part serial
E5006253
Condition
Failed
Location
Zone 120
Part time
7,303 hours, 2,832 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB OUT EN ROUTE, PRIOR TO FLAP RETRACTION, RECD ECAM WARNING FOR GREEN HYD SYS FAILURE IND LOW GREEN PRESS AND QTY. FOLLOWED ECAM PROCED AND TURNED OFF NR 1 ENG DRIVEN HYD PUMP (EDP), PWR TRANS UNIT (PTU), TURNED EDP BACK ON AND PRESS RETURNED TO NML, TURNED ON PTU AND ECAM WARNING FOR GREEN HYD SYS FAILURE REAPPEARED. RE-ACCOMPLISHED PROCEDURES, TURNED EDP BACK ON. MAINT TROUBLESHOT, OPERATIONAL TEST OF GREEN HYD SYS WAS GOOD. RAN ENG AND OPERATED THE PTU, PTU WAS GOOD IN BOTH DIRECTIONS, ALL PRESS AND QTY INDICATED NORMAL. AS PRECAUTION REMOVED AND REPLACED SIGNAL DATA ACQUISITION UNIT (SDAC), OPERATIONAL CHECK WAS GOOD.

More about the Airbus A319-132