Service difficulty report · Power Supply · Airbus A320232

Difficulty date
September 8, 2003
Submitted
September 9, 2003
Operation
Air carrier
Aircraft
N619AW
Make and model
Airbus A320232
Aircraft serial
527
Aircraft time
25,401 hours, 11,543 cycles
Part
Power Supply
Part number
32145410
Part serial
3712
Condition
Discharged
Location
Zone 241
Part time
7,748 hours, 2,968 cycles
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING INSPECTION TEST OF EMERGENCY LIGHTS BY "EMERGENCY LIGHT SYSTEM" PUSH BUTTON FAILED. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT BATTERY, AND EMERGENCY POWER SUPPLY UNIT (11WL), OPERATIONAL CHECK FAILED, PART BAD FROM SUPPLY. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (11WL) AGAIN AND SYSTEM FUNCTIONAL CHECK WAS GOOD. PART NAME; ESPU, MFG; DIEHL GMBH, P/N; 3214-54-10, S/N; 3309, TT; 7412, TC; 2827, LOC; ZONE 241, REASON; PART BAD FROM SUPPLY.